AGO-1 (20655) Message -- ARGOS Time 327/11:38:07.000 Rack Temperature -133.93 C Hut Temperature 5.28 C Ext. Temperature -37.86 C 12V 14.50 V 5V 5.06 V Iridium Temperature 38.61 C AWP Current 24.66 A Rack Heater Current 0.51 A Wind Speed 12.16 mph Wind Direction 279.12 deg Hut Heater Current 0.69 A Ext. Heater Current 23.93 A PV Combined Current 3.05 A Instrument Current 2.25 A Rack Heater EN 0.00 V Battery Current 0.46 A Hut Heater EN 0.00 V Ext. Heater EN 4.86 V Bus Voltage 29.81 V Battery Voltage 26.96 V (Negative heater currents indicate calibration error. Negative battery current indicates discharge, positive indicates charge) AGO-2 (08073) Message -- ARGOS Time 327/08:39:38.000 Rack Temperature -0.60 C Hut Temperature -8.44 C Ext. Temperature -24.13 C 12V 12.97 V 5V 5.06 V Iridium Temperature 99.40 C AWP Current 0.87 A Rack Heater Current 1.05 A Wind Speed 1.18 mph Wind Direction 156.02 deg Hut Heater Current 2.32 A Ext. Heater Current -1.85 A PV Combined Current 2.32 A Instrument Current 1.69 A Rack Heater EN 4.86 V Battery Current 0.99 A Hut Heater EN 4.82 V Ext. Heater EN 0.00 V Bus Voltage 29.64 V Battery Voltage 27.63 V (Negative heater currents indicate calibration error. Negative battery current indicates discharge, positive indicates charge) AGO-3 (20654) Message -- ARGOS Time 327/11:36:22.000 Rack Temperature 7.24 C Hut Temperature -273.15 C Ext. Temperature -26.09 C 12V 14.58 V 5V 4.94 V Iridium Temperature 19.01 C AWP Current 7.95 A Rack Heater Current 3.41 A Wind Speed 3.92 mph Wind Direction 339.24 deg Hut Heater Current 3.96 A Ext. Heater Current -0.40 A PV Combined Current 1.42 A Instrument Current 2.16 A Rack Heater EN 4.84 V Battery Current 0.07 A Hut Heater EN 4.82 V Ext. Heater EN 0.00 V Bus Voltage 30.14 V Battery Voltage 26.96 V (Negative heater currents indicate calibration error. Negative battery current indicates discharge, positive indicates charge)